[1]王贺,王欣,靳静娜,等.经颅磁刺激联合经颅直流电刺激在大脑皮层电场分布的研究*[J].生物医学工程研究,2019,01:11-15.
WANG He,WANG Xin,JIN Jingna,et al.Distribution of electric field in cerebral cortex when combined with transcranial magnetic stimulation and transcranial direct current stimulation to stimulate different regions of the cerebral cortex[J].Journal of Biomedical Engineering Research,2019,01:11-15.
点击复制
经颅磁刺激联合经颅直流电刺激在大脑皮层电场分布的研究*(PDF)
《生物医学工程研究》[ISSN:1006-6977/CN:61-1281/TN]
- 期数:
-
2019年01期
- 页码:
-
11-15
- 栏目:
-
- 出版日期:
-
2019-03-25
文章信息/Info
- Title:
-
Distribution of electric field in cerebral cortex when combined with transcranial magnetic stimulation and transcranial direct current stimulation to stimulate different regions of the cerebral cortex
- 文章编号:
-
1672-6278 (2019)01-0011-05
- 作者:
-
王贺1; 王欣1; 靳静娜1; 李颖1; 刘志朋1; 殷涛 1; 2△
-
1.中国医学科学院 北京协和医学院 生物医学工程研究所, 天津 300192;2.中国医学科学院神经科学中心,北京 100730
- Author(s):
-
WANG He1; WANG Xin1; JIN Jingna1; LI Ying1; LIU Zhipeng1; YIN Tao1; 2
-
1.Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China;2.Neuroscience Center,Chinese Academy of Medical Sciences ,Beijing 100730,China
-
- 关键词:
-
经颅磁刺激; 经颅直流电刺激; 电场分布; 仿真; SimNibs
- Keywords:
-
Transcranial magnetic stimulation; Transcranial direct current stimulation; Electric field distribution; Simulation; SimNibs
- 分类号:
-
R318
- DOI:
-
10.19529/j.cnki.1672-6278.2019.01.03
- 文献标识码:
-
A
- 摘要:
-
经颅磁刺激 (transcranial magnetic stimulation ,TMS)和经颅直流电刺激 (transcranial direct current stimulation,tDCS)均可用于调控大脑皮层的兴奋性。此前两种技术很少被用于同时刺激大脑皮层的两个不同区域,近期研究表明,同时刺激大脑皮层两个相互连接的区域可以提高刺激效果。为了确保应用安全性并给出实验指导,本研究使用SimNibs进行仿真计算,研究同时应用TMS和tDCS时在大脑皮层产生的两个电场之间的相互作用。结果表明,同时应用TMS和tDCS是安全的,且TMS和tDCS之间的相互作用受线圈和电极之间相对位置的影响。
- Abstract:
-
Both transcranial magnetic stimulation(TMS)and transcranial direct current stimulation (tDCS) can be used to increase and to reduce the excitability of the cortex, but the two technologies are rarely used to stimulate the two positions of the human brain simultaneously. To ensure safety and to give experimental guidance, some simulations using SimNibs with different electrode and coil positions were performed and the interaction parameters were calculated. The results demonstrate that applying TMS with tDCS simultaneously is safe. And the interaction between TMS and tDCS is affected by the relative position between the coil and the electrode.