|本期目录/Table of Contents|

[1]刘子凡,许苑晶,柳毅浩,等.基于3D打印的医学三维重构软件系统的精度研究*[J].生物医学工程研究,2020,03:219-225.
 LIU Zifan,XU Yuanjing,LIU Yihao,et al.Research on the accuracy of medical 3D reconstruction software system based on 3D printing[J].Journal of Biomedical Engineering Research,2020,03:219-225.
点击复制

基于3D打印的医学三维重构软件系统的精度研究*(PDF)

《生物医学工程研究》[ISSN:1006-6977/CN:61-1281/TN]

期数:
2020年03期
页码:
219-225
栏目:
出版日期:
2020-09-25

文章信息/Info

Title:
Research on the accuracy of medical 3D reconstruction software system based on 3D printing
文章编号:
1672-6278-(2020)03-0219-07
作者:
刘子凡1许苑晶2柳毅浩3刘非4张敏4王文豪1邓迁1顾越兴2戴尅戎3王金武23△
1.西南交通大学医学院,成都 610031;2.上海交通大学生物医学工程学院,上海 200030;3.上海市骨科内植物重点实验室,上海交通大学医学院附属第九人民医院骨科,上海 200011;4.上海昕健医疗技术有限公司,上海 201800
Author(s):
LIU Zifan1 XU Yuanjing2 LIU Yihao3 LIU Fei4 ZHANG Min4 WANG Wenhao1 DENG Qian1 GU Yuexing2 DAI Kerong3WANG Jinwu23
1.College of Medicine, Southwest Jiaotong University, Chengdu 610031, China;2. School of Biomedical Engineering,Shanghai Jiao Tong University,Shanghai 200030,China;3.Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, The Ninth People’s Hospital Affilicated to School of Medicine of Shanghai Jiao Tong University, Shanghai 200011;4.Shanghai Arigin Medical Co.,Ltd.,Shanghai 201800
关键词:
体模医学图像三维重构精度稳定性
Keywords:
Phantom Medical image Three-dimensional reconstructionPrecision Stability
分类号:
R318
DOI:
10.19529/j.cnki.1672-6278.2020.03.01
文献标识码:
A
摘要:
为研究Arigin 3D Pro医学三维重构软件的精度和稳定性,制作3种形状的CT体模和球形的MRI体模作为实体模型。选取3种CT设备和1种MRI设备对制作的实体模型进行数据扫描,选择重构经验不同的3名操作者使用Arigin 3D Pro医学三维重构软件进行重构,每次重构均使用Geomagic Wrap测量3次参数,并用游标卡尺测量实体模型参数。结果表明,重构的三维模型与实体模型的相对误差占实体模型的0.09%~1.28%,该软件可对不同品牌的CT、MRI扫描数据进行处理,一致性指标ICC为0.930, 具有通用性。同一操作者多次重构相同模型的组内误差占实体模型的0.56%~0.82%,不同操作者重构的三维模型存在组间差异,重构经验越少,差异越大。通过Catphan体模对Arigin 3D Pro医学三维重构软件的定量评价,表明该软件重构的模型精度准确性较高,稳定性较好。
Abstract:
To study the precision and stability of the Arigin 3D Pro software,we produced three shapes CT phantom and spherical MRI phantom as solid models. 3 different brands of CT equipment and 1 brand of MRI equipment were selected to scan the data. The vernier caliper was used to measure parameters corresponding to the solid model, and 3 operators with diffetent reconstruction experience were choosed for the model reconstruction, and Geomagic software was used to measure parameters three times for each reconstruction. Compared with the solid model, the 3D model with different reconstructed shapes had a small relative deviation, was 0.09%~1.28% of the solid model. The software was versatile and could process CT,MRI scan data of any brand, the consistency index ICC was 0.930. The intra group error of the same model reconstructed many times by the same operator was 0.56%~0.82% of the solid model. There were differences among the three-dimensional models reconstructed by different operators. The less experience of reconstruction, the greater the difference was. Using the phantom to evaluate the diagnostic image processing software quantitatively show that the model reconstructed by the software has higher accuracy and better stability.

参考文献/References

备注/Memo

备注/Memo:
(收稿日期:2020-03-05)国家重点研发计划项目( 2018YFC2001300);上海市科委项目(19XD1434200/19441908700/19441917500); 上海交通大学医学院地高大双百人计划项目(20152224)。△通信作者Email:jinwu_wang@163.com
更新日期/Last Update: 2020-10-15