[1]夏攀,周瑞石,赵荣建,等.一种基于射血前期的连续血压估计方法*[J].生物医学工程研究,2020,03:300-305.
 XIA Pan,ZHOU Ruishi,ZHAO Rongjian,et al.A method of continuous blood pressure estimation based on pre-ejection period[J].Journal of Biomedical Engineering Research,2020,03:300-305.
点击复制

一种基于射血前期的连续血压估计方法*(PDF)

《生物医学工程研究》[ISSN:1006-6977/CN:61-1281/TN]

期数:
2020年03期
页码:
300-305
栏目:
出版日期:
2020-09-25

文章信息/Info

Title:
A method of continuous blood pressure estimation based on pre-ejection period
文章编号:
1672-6278(2020)03-300-06
作者:
夏攀12周瑞石12赵荣建1何征岭2陈贤祥1△方震1△
1.中国科学院空天信息创新研究院,北京100190;2.中国科学院大学电子电气与通信工程学院,北京100049
Author(s):
XIA Pan12 ZHOU Ruishi12 ZHAO Rongjian1 HE Zhengling2 CHEN Xianxiang1 FANG Zhen1
1. Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China;2. School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049
关键词:
射血前期脉搏波到达时间脉搏波传导时间连续血压估计相关性用户依从性
Keywords:
Pre-ejection period Pulse arrival time Pulse transit time Continuous blood pressure estimation The correlation User compliance
分类号:
R318
DOI:
10.19529/j.cnki.1672-6278.2020.03.14
文献标识码:
A
摘要:
常规基于脉搏波到达时间的连续血压监测系统需要同时佩戴心电极和指套式脉搏波传感器,对用户的依从性要求较高。为解决此问题,本研究基于射血前期与血压具有较高相关性的机理,提出了一种基于射血前期的连续血压估计方法。 本研究招募了13名男性受试者,通过与美国顺泰公司的SunTech Oscar2动态血压监测仪进行对比测试,验证了所提血压估计方法的可行性。通过小样本的实验观测发现,本研究方法在一定程度上满足美国医疗仪器促进协会(AAMI)对于血压测量准确性的要求。该方法的准确性与基于脉搏波到达时间的血压估计方法相当,且能够明显降低用户的依从性要求,在便携式连续血压测量方面具有潜力。
Abstract:
The conventional continuous blood pressure monitoring system based on the pulse arrival time needs to wear both adhesive electrodes and fingertip pulse sensor, which requires high user compliance.In order to solve the above problems, according to the mechanism of high correlation between pre-ejection period and blood pressure,we proposed a continuous blood pressure estimation method based on pre-ejection period. 13 male subjects were recruited to verify the feasibility of the proposed method. The SunTech Oscar2 ambulatory blood pressure monitor was the reference device.It was found by experimental observation of a small sample that the proposed method met the accuracy requirements of the AAMI.The accuracy of the proposed method is comparable to that of the blood pressure estimation method based on the pulse arrival time. The proposed method can significantly reduce user compliance requirements,has potentiality in portable devices of monitoring continuous blood pressure.

参考文献/References

备注/Memo

备注/Memo:
(收稿日期:2020-01-28)国家重点研发计划项目(2016YFC1304302;2018YFC2001802);本论文由国防科技创新特区项目支持。△通信作者Email:zfang@mail.ie.ac.cn;xxchen@mail.ie.ac.cn
更新日期/Last Update: 2020-10-16