|本期目录/Table of Contents|

[1]袁子维,曾正,李冬果,等.兔眼角膜胶原交联后角膜动态响应参数的变化*[J].生物医学工程研究,2022,01:13-19.
 YUAN Ziwei,ZENG Zheng,LI Dongguo,et al.Changes of dynamic corneal response parameters after collagen crosslinking in rabbit corne[J].Journal of Biomedical Engineering Research,2022,01:13-19.
点击复制

兔眼角膜胶原交联后角膜动态响应参数的变化*(PDF)

《生物医学工程研究》[ISSN:1006-6977/CN:61-1281/TN]

期数:
2022年01期
页码:
13-19
栏目:
出版日期:
2022-03-25

文章信息/Info

Title:
Changes of dynamic corneal response parameters after collagen crosslinking in rabbit corne
文章编号:
1672-6278 (2022)01-0013-07
作者:
袁子维12曾正12李冬果12张海霞12李林12△
1.首都医科大学生物医学工程学院,北京 100069;2.首都医科大学 临床生物力学应用基础研究北京市重点实验室,北京 100069
Author(s):
YUAN Ziwei12 ZENG Zheng12 LI Dongguo12 ZHANG Haixia12 LI Lin12
1.School of Biomedical Engineering, Capital Medical University, Beijing 100069, China;2. Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing 100069
关键词:
角膜胶原交联可视化角膜生物力学分析仪角膜动态响应参数硬度弹性模量变化规律
Keywords:
Corneal collagen crosslinking Corneal visualisation scheimpflug technology Dynamic corneal response parameters Stiffness Elastic modulus Change rule
分类号:
R318.01;R779.6
DOI:
10.19529/j.cnki.1672-6278.2022.01.03
文献标识码:
A
摘要:
本研究应用可视化角膜生物力学分析仪,于角膜胶原交联术前与术后3月内不同时间对兔眼角膜实施测试,探讨角膜胶原交联后,角膜动态响应参数随术后时间的变化,并计算角膜弹性模量,分析生物力学参数与中央角膜厚度、生物力学矫正眼压的相关性。研究发现,术后1周内角膜动态响应参数变化明显,术后2~3月开始趋于稳定。交联后4周角膜弹性模量增加78.7%,交联效果较好。生物力学参数与中央角膜厚度、生物力学矫正眼压均有相关性,评估角膜生物力学性质同时要关注角膜厚度与眼压的影响。本研究探讨角膜胶原交联后生物力学特性的变化,为交联处置术式的个性化和评估交联手术术后效果提供参考。
Abstract:
In this study, corneal visualisation scheimpflug technology was used to test rabbit corneas at different times before and within 3 months after corneal collagen crosslinking, to investigate the changes of dynamic corneal response parameters after corneal collagen crosslinking with postoperative time, and to calculate the corneal elastic modulus. The correlation of biomechanical parameters with central corneal thickness and biomechanical correction of intraocular pressure(IOP)was analyzed. The results showed that the corneal dynamic response parameters changed significantly in the first week after surgery, and tended to be stable from 2 to 3 months after surgery. Four weeks after crosslinking, the elastic modulus of the cornea increased by 78.7% compared with that before the operation, and the crosslinking effect was good. Biomechanical parameters were correlated with central corneal thickness and biomechanical correction of IOP, and the influence of corneal thickness and IOP should be paid attention to in the evaluation of corneal biomechanical properties. This study investigates the changes of biomechanical properties of corneal collagen after crosslinking, and provides reference for the individualization of crosslinking treatment methods and the evaluation of postoperative effects of crosslinking surgery.

参考文献/References

备注/Memo

备注/Memo:
(2021-06-25)国家自然科学基金资助项目(31370952,31470914)。△通信作者Email:lil@ccmu.edu.cn
更新日期/Last Update: 2022-04-20